Skip to main content

AIRWORTHINESS DIRECTIVE AD/BEECH 33/48 Amdt 1

Beechcraft 33 Debonair · Other Documents

Free account — keep the POHs & checklists you reference in one place.

Overview

This document is an Airworthiness Directive (AD) issued by the Civil Aviation Safety Authority (CASA) for the Beechcraft 33 and 35-33 series aircraft, specifically the Debonair and Bonanza models. The directive addresses safety concerns related to the forward elevator control cable assembly, which has been linked to instances of failure that could lead to loss of control during flight. The AD mandates inspections and potential replacements of the elevator cable assembly to ensure the safety and airworthiness of the aircraft. The document outlines compliance requirements, inspection procedures, and the effective dates for these actions, emphasizing the importance of adhering to the manufacturer's Instructions for Continuing Airworthiness (ICA).

  • Inspect the forward elevator control cable assembly for wear, broken wires, and corrosion.
  • Replace any defective forward elevator cable assembly immediately.
  • Do not install any cable assembly that has been removed due to defects.
  • Compliance with inspection requirements is mandatory before further flight.
  • A single positioning flight is allowed for inspection if necessary.

Document

Source

Originally published by services.casa.gov.au. Sprinkle hosts a reference copy with an added summary, specifications and searchable full text.

Report a problem or request removal

Document details

Type
Other Documents
Year
2012
Pages
3
File size
47 KB
Publisher
services.casa.gov.au
Documentation completeness
3/7

Most owners only have the POH. Here's the essential set for the Beechcraft 33 Debonair.

More Beechcraft 33 Debonairmanuals & documents

See all 19

In this document

Applicability

The Airworthiness Directive applies to all Beechcraft Debonair and Bonanza aeroplanes equipped with the specified forward elevator control cable configuration. This includes both the Beechcraft 33 and 35-33 models.

Requirements

The AD outlines specific requirements for inspecting the forward elevator control cable assembly for wear, broken wires, and corrosion. If any defects are found, the cable assembly must be replaced. The directive also prohibits the installation of any cable assembly that has been removed due to defects.

Compliance

Compliance with the inspection requirements is mandatory. For aircraft that have not had the forward elevator cable assembly inspected or replaced within the last maintenance release period, inspections must be completed before further flight. A single positioning flight is permitted for aircraft unable to undergo inspection immediately.

Background

The directive was prompted by reports of forward elevator cable failures, which could lead to serious safety issues. The AD emphasizes the need for immediate inspections and the removal of cables older than 15 years, although some requirements have been adjusted based on new manufacturer guidance.

Safety notes

  • Failure to comply with the AD may result in loss of control of the aircraft.
  • Immediate inspection is required for cables over 15 years old.

Full document text

COMMONWEALTH OF AUSTRALIA (Civil Aviation Safety Regulations 1998), PART 39.001(1) CIVIL AVIATION SAFETY AUTHORITY SCHEDULE OF AIRWORTHINESS DIRECTIVES Page 1 of 3 AIRWORTHINESS DIRECTIVE On the effective date specified below, and for the reasons set out in the background section, the CASA delegate whose signature appears below revokes Airworthiness Directive (AD) AD/BEECH 33/48 and issues the following AD under subregulation 39.001(1) of CASR 1998. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section. Beechcraft 33 and 35-33 (Debonair/Bonanza) Series Aeroplanes AD/BEECH 33/48 Amdt 1 Forward Elevator Cable 4/2012 Applicability: All Beechcraft Debonair/Bonanza aeroplanes fitted with the forward elevator control cable configuration as detailed in figure 1 of this AD. Requirement: 1. Inspect the forward elevator control cable assembly for wear, broken wires and corrosion; or replace the forward elevator cable assembly. 2. Remove from service any forward elevator control cable assembly found to be defective as a result of inspection conducted in accordance with Requirement 1 of this AD. 3. Do not install on any aircraft a cable assembly or parts thereof that have been removed in accordance with Requirement 2 of this AD. Note 1: Inspections carried out in accordance with FAA AC 43-13-1B, chapter 7, Section 8, paragraph 7-149(d) or Beechcraft maintenance data are an acceptable means of compliance for the inspection called up by Requirement 1 of this AD. Compliance: For Requirement 1. For those aircraft that have not had the forward elevator cable assembly replaced or inspected within the last maintenance release period - Remains unchanged as - Before further flight after the 16 January 2012 (the effective date of the original issue of this AD). For those aircraft located where the inspection cannot be carried out - one positioning flight (pilot only) is allowed to a place where the inspection can be carried out. Aircraft that have had the forward elevator cable assembly replaced or inspected in accordance with the original issue of this AD are considered to be in compliance with Requirement 1 of this AD. COMMONWEALTH OF AUSTRALIA (Civil Aviation Safety Regulations 1998), PART 39.001(1) CIVIL AVIATION SAFETY AUTHORITY SCHEDULE OF AIRWORTHINESS DIRECTIVES Beechcraft 33 and 35-33 (Debonair/Bonanza) Series Aeroplanes AD/BEECH 33/48 Amdt 1 (continued) Page 2 of 3 For Requirement 2. Before further flight. For Requirement 3. After the effective date of this AD. This Amendment becomes effective on 27 February 2012. Background: CASA has received a report describing a forward elevator cable failure (separation) immediately prior to take-off. The elevator remained firmly in the full ‘down’ position due to system spring tension. A second aircraft was inspected at the owner’s request immediately following the discovery of the failed cable. The forward elevator cable in this aircraft was found to be extensively frayed in the same location as the failed cable. Since the original issue of this AD, CASA has received reports of 5 more cables found to be unserviceable. This AD required immediate inspection of the forward elevator cable and replacement for elevator cables over 15 years old, and required continuing inspections of the entire elevator control system to preclude the unanticipated failure of the elevator flight control system which may result in loss of control of the aircraft. Requirements for repeat inspections and the mandatory removal of cables in excess of 15 years in service have been removed from this AD following the publication of Instructions for Continuing Airworthiness (ICA) by the manufacturer. Those ICA are considered satisfactory to ensure the failure of the elevator cable does not occur provided that the ICA is adhered to during the inspection process. This Amendment clarifies the applicability section of the AD by introducing additional criteria (Figure 1) to assist the registered operator in determining whether this AD is applicable to their aircraft. The original issue of this AD became effective on 16 January 2012. COMMONWEALTH OF AUSTRALIA (Civil Aviation Safety Regulations 1998), PART 39.001(1) CIVIL AVIATION SAFETY AUTHORITY SCHEDULE OF AIRWORTHINESS DIRECTIVES Beechcraft 33 and 35-33 (Debonair/Bonanza) Series Aeroplanes AD/BEECH 33/48 Amdt 1 (continued) Page 3 of 3 Figure 1 - Forward Elevator Control Cable - Adapted from Beechcraft Illustrated Parts Catalogue. Peter Boyd Delegate of the Civil Aviation Safety Authority 23 February 2012