SUPPLEMENT S02
DIAMOND DA42 · Flight Manual Supplement
Overview
This document is a supplement to the Airplane Flight Manual for the Diamond DA42 equipped with the Garmin GFC 700, specifically detailing the Continuous Flow Oxygen System. It includes operational procedures, limitations, and performance data related to the oxygen system.
- The DA42 can be equipped with a continuous flow oxygen system for use up to 18,000 ft.
- The document is EASA approved under Approval Number EASA.A.C.04008.
- Max structural cruising speed is vNO = 151 KIAS.
- Never exceed speed in smooth air is vNE = 188 KIAS.
- Smoking is prohibited while the oxygen system is in use.
- Oxygen pressure must be checked before climbing above 10,000 ft.
- The oxygen system provides supplemental oxygen for each pilot and passenger.
- A leak in the oxygen system may increase the risk of fire.
Document
Source
Originally published by acaeronautics.com. Sprinkle hosts a reference copy with an added summary, specifications and searchable full text.
Document details
- Type ·
- Flight Manual Supplement
- Year ·
- 2007
- File size ·
- 481 KB
- Publisher ·
- acaeronautics.com
- Language ·
- en
Specifications & performance
Extracted from this document.
Specifications
- Oxygen system max altitude (ft) ·
- 18000
Performance
- Oxygen duration 1 user 10000ft hours ·
- 20.3
- Oxygen duration 1 user 15000ft hours ·
- 16
- Oxygen duration 1 user 18000ft hours ·
- 7.4
V-speeds
- VNE_KIAS ·
- 188
- VNO_KIAS ·
- 151
What is the SUPPLEMENT S02?
The SUPPLEMENT S02 is a flight manual supplement for the DIAMOND DA42, dated 2007.
Where does the SUPPLEMENT S02 come from?
This copy of the SUPPLEMENT S02 was originally published by acaeronautics.com and is hosted on Sprinkle as a free, searchable reference copy.
What year was the SUPPLEMENT S02 published?
The SUPPLEMENT S02 — the DIAMOND DA42 flight manual supplement on file — is dated 2007.
Most owners only have the POH. Here's the essential set for the DIAMOND DA42.
- Pilot's Operating Handbook / AFM
- Checklist
- Maintenance Manual
- Parts Catalog (IPC)
- Systems & Wiring
- Service Bulletins on file
- Type Certificate (TCDS)
More DIAMOND DA42manuals & documents
Related documents
- Oxygen System AFM SupplementMOONEY M20J · Systems Description
- Wiring Diagram for Cirrus SR22TCirrus SR22T · Wiring Diagrams
- Precise Flight Fixed Oxygen System For The Cirrus SR22/SR22T Pilot’s Operating Handbook and Airplane Flight Manual SupplementCirrus SR22T G7 · Pilot's Operating Handbook
- BEECHCRAFT SUPER KING AIR B200/B200CBeechcraft King Air 200 · Checklist
- Master Minimum Equipment List (MMEL)PIPER M700 · Checklist
In this document
General
The DA 42 with Garmin GFC 700 can be equipped with an optional continuous flow oxygen system that distributes supplemental oxygen for each pilot and passenger up to 18,000 ft.
Operating Limitations
There are no specific operating limitations stated for the oxygen system.
Emergency Procedures
Procedures for cabin smoke, fire, and oxygen pressure loss above 10,000 ft are outlined, including the need for an emergency descent.
Normal Operating Procedures
Includes checklists for pre-flight inspection and procedures for using the oxygen system above 10,000 ft.
Performance
Details on the duration of oxygen supply based on altitude and number of users, including tables for standard and Oxysaver® cannulas.
Safety notes
- Max structural cruising speed is vNO = 151 KIAS.
- Never exceed speed in smooth air is vNE = 188 KIAS.
- Smoking is prohibited while the oxygen system is in use.
- If the oxygen pressure gauge indicates a cylinder pressure of 200 psi, initiate descent to below 10,000 ft.
- A leak in the oxygen system may excessively increase the risk of fire.
Full document text
DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System SUPPLEMENT S04 TO THE AIRPLANE FLIGHT MANUAL DA 42 with Garmin GFC 700 (OÄM 42-102) CONTINUOUS FLOW OXYGEN SYSTEM Doc. No. : 7.01.06-E Date of Issue : 20-Dec-2007 Design Change Advisory : OÄM-42-055 This Supplement to the Airplane Flight Manual is EASA approved under Approval Number EASA.A.C.04008. DIAMOND AIRCRAFT INDUSTRIES GMBH N.A. OTTO-STR. 5 A-2700 WIENER NEUSTADT AUSTRIA 9-S04-1 Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-2 20-Dec-2007 Rev. 0 Doc. # 7.01.06-E Intentionally left blank. DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 09-Mar-2021 Rev. 2 Page 9-S04-3 0.1 RECORD OF REVISIONS Rev. No. Reason Chap- ter Page(s) Date of Revision Approval Note Verification Date Inserted Signature 1 OÄM 42- 055/i Diagrams Improved, Corrections 0 9-S04-3 through 9-S04-6 10-Nov-2011 Rev. 1 to AFM Supplement S04 to AFM Doc.No. 7.01.06-E is approved under the authority of DOA No. EASA 21J.052 21-Nov- 2011 5, 6, 7, 8 9-S04-14 through 9-S04-34 2 OÄM 42- 055/n Correction of max. filling pressure 0, 7 9-S04-03, 9-S04-04, 9-S04-05, 9-S04-24 09-Mar-2021 The technical content of this document is approved under the authority of DOA ref. EASA 21J.052 06-May- 2021 Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-4 09-Mar-2021 Rev. 2 Doc. # 7.01.06-E 0.2 LIST OF EFFECTIVE PAGES Chapter Page Date 0 9-S04-1 9-S04-2 9-S04-3 9-S04-4 9-S04-5 9-S04-6 20-Dec-2007 20-Dec-2007 09-Mar-2021 09-Mar-2021 09-Mar-2021 10-Nov-2011 1 9-S04-7 20-Dec-2007 2 appr. 9-S04-7 20-Dec-2007 3 9-S04-8 9-S04-9 9-S04-10 20-Dec-2007 20-Dec-2007 20-Dec-2007 4A 9-S04-11 9-S04-12 9-S04-13 20-Dec-2007 20-Dec-2007 20-Dec-2007 4B 9-S04-13 20-Dec-2007 5 9-S04-14 9-S04-15 9-S04-16 9-S04-17 9-S04-18 9-S04-19 9-S04-20 9-S04-21 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 09-Mar-2021 Rev. 2 Page 9-S04-5 6 9-S04-22 10-Nov-2011 7 9-S04-23 9-S04-24 9-S04-25 9-S04-26 9-S04-27 9-S04-28 9-S04-29 9-S04-30 9-S04-31 10-Nov-2011 09-Mar-2021 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 10-Nov-2011 8 9-S04-32 9-S04-33 9-S04-34 10-Nov-2011 10-Nov-2011 10-Nov-2011 Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-6 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E 0.3 TABLE OF CONTENTS 1. GENERAL ..............................................................................................9-S04-7 2. OPERATING LIMITATIONS ..................................................................9-S04-7 3. EMERGENCY PROCEDURES ..............................................................9-S04-8 4A. NORMAL OPERATING PROCEDURES ...............................................9-S04-11 4B. ABNORMAL OPERATING PROCEDURES ..........................................9-S04-13 5. PERFORMANCE ...................................................................................9-S04-14 6. MASS AND BALANCE ..........................................................................9-S04-22 7. DESCRIPTION OF THE AIRPLANE AND ITS SYSTEMS ....................9-S04-23 8. AIRPLANE HANDLING, CARE AND MAINTENANCE ..........................9-S04-32 DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 20-Dec-2007 Rev. 0 Page 9-S04-7 1. GENERAL The DA 42 with Garmin GFC 700 (OÄM 42-102) can be equipped with an optional continuous flow oxygen system. It distributes supplemental oxygen for each pilot and passenger up to 18,000 ft. 2. OPERATING LIMITATIONS None. Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-8 20-Dec-2007 Rev. 0 Doc. # 7.01.06-E 3. EMERGENCY PROCEDURES 3.8 SMOKE AND FIRE 3.8.6 CABIN SMOKE ABOVE 10,000 FT 1. OXYGEN .............................................. check ON initiate an emergency descent: 2. FLAPS ................................................... UP 3. LANDING GEAR ................................... DOWN 4. POWER lever ........................................ IDLE 5. Airspeed ................................................ as required WARNING Max. structural cruising speed . . . . . . . . vNO = 151 KIAS Never exceed speed in smooth air . . . . .vNE = 188 KIAS when passing 10,000 ft: 6. OXYGEN .............................................. OFF 7. Land at the nearest suitable airfield. END OF CHECKLIST DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 20-Dec-2007 Rev. 0 Page 9-S04-9 3.8.7 CABIN FIRE ABOVE 10,000 FT 1. OXYGEN ............................................... push OFF initiate an emergency descent: 2. FLAPS ................................................... UP 3. LANDING GEAR .................................... DOWN 4. POWER lever ........................................ IDLE 5. Airspeed ................................................. as required WARNING Max. structural cruising speed . . . . . . . . vNO = 151 KIAS Never exceed speed in smooth air . . . . vNE = 188 KIAS 6. Land at the nearest suitable airfield. END OF CHECKLIST 3.9 OTHER EMERGENCIES 3.9.11 OXYGEN PRESSURE LOSS ABOVE 10,000 FT 1. OXYGEN ............................................... push OFF 2. Oxygen pressure.................................... checked, note down initiate an emergency descent: 3. FLAPS ................................................... UP 4. LANDING GEAR .................................... DOWN 5. POWER lever ........................................ IDLE 6. Airspeed ................................................. as required CONTINUED Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04
Show full textShow less
Page 9-S04-10 20-Dec-2007 Rev. 0 Doc. # 7.01.06-E WARNING Max. structural cruising speed . . . . . . . . vNO = 151 KIAS Never exceed speed in smooth air . . . . vNE = 188 KIAS when passing 10,000 ft: 7. Oxygen pressure ................................... check if oxygen pressure is constant, continue flight: 8. Airspeed .............................................. check 9. LANDING GEAR ................................. UP 10. POWER lever ...................................... as required 11. Airspeed .............................................. as required if oxygen pressure drops, abort flight: 8. Land at the nearest suitable airfield. WARNING A leak in the oxygen system may excessively increase the risk of fire. END OF CHECKLIST DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 20-Dec-2007 Rev. 0 Page 9-S04-11 4A. NORMAL OPERATING PROCEDURES 4A.6 CHECKLISTS FOR NORMAL OPERATING PROCEDURES NOTE This supplement has been created in compliance with the requirement and rules of JAR-23; limit altitude according rules of JAR-OPS1. 4A.6.1 PRE-FLIGHT INSPECTION I. Cabin check front baggage compartment: a) Front baggage compartment ................. check, no flammable fluids, oils and greases are in the nose baggage compartment. oxygen system: a) Cannulas ............................................... visual inspection b) Mask ...................................................... visual inspection NOTE There must be 4 cannulas (or at least one for each occupant) and 1 mask (type: MSK-AEM) on board. Further 4 connection hoses are required. The cannulas and masks must be accessible during flight. c) Oxygen pressure .................................... check, note down d) Oxygen duration chart ........................... observe/ calculate duration (refer to Chapter 5) END OF CHECKLIST Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-12 20-Dec-2007 Rev. 0 Doc. # 7.01.06-E 4A.6.22 FLIGHT ABOVE 10,000 FT USING OXYGEN SYSTEM before climbing above 10,000 ft: 1. Oxygen pressure .................................. check 2. Cannula, mask and hose ...................... adjust to face (refer to Chapter 7) 3. Delivery hose......................................... plug into outlet assigned to seat 4. OXYGEN push/pull knob ....................... pull ON NOTE When the oxygen system is turned on, oxygen will flow continuously at the appropriate rate of flow selected for the altitude with minor adjustments to the needle valve thumb wheel. 5. Cannula hose flowmeter........................ adjust to altitude NOTE Check each occupant’s oxygen cannula adjustment and flowmeter setting. Recheck oxygen pressure indication from time to time. NOTE Always place the flowmeter in a position where it is in the normal scan area of the user. WARNING Smoking is in no case permitted in the DA 42. It is especially dangerous while the oxygen system is in use. CONTINUED DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 20-Dec-2007 Rev. 0 Page 9-S04-13 WARNING If the oxygen pressure gauge indicates a cylinder pressure of 200 psi, initiate descent to reach an altitude below 10,000 ft. after descending below 10,000 ft: 1. Delivery hose ........................................ unplug, or turn needle valve thumb wheel clockwise 2. OXYGEN push/pull knob ....................... PUSH OFF 3. Cannula, mask and hose ....................... displace from face, as required END OF CHECKLIST 4B. ABNORMAL OPERATING PROCEDURES None. Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-14 20-Dec-2007 Rev. 0 Doc. # 7.01.06-E 5. PERFORMANCE 5.3 PERFORMANCE TABLES AND DIAGRAMS 5.3.14 OXYGEN SYSTEM a) Duration quick check table and diagram - masks and standard cannulas Duration using masks and standard cannulas (hours), Oxygen cylinder filled with 1850 PSI, Number of users 10,000 ft (MSL) 15,000 ft (MSL) 18,000 ft (MSL) 1 20.3 16 7.4 2 10 8 3.7 3 6.8 5.3 2.5 4 5 4 1.8 DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-15 Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-16 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E b) Duration quick check table and diagram – Oxysaver® cannulas Duration using Oxysaver® cannulas (hours), Oxygen cylinder filled with 1850 PSI Number of users 10,000 ft (MSL) 15,000 ft (MSL) 18,000 ft (MSL) 1 60 50 32 2 29.8 25 16 3 20 16.5 10.6 4 15 12 8 DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-17 Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-18 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E c) Exact duration calculation of the oxygen system The duration of supplying supplemental oxygen to the occupants provided by the Aerox continuous flow oxygen system depends on the following facts: -) Oxygen cylinder pressure -) number of users- and types of dispensing equipment- individual oxygen mass flow -) flight altitude The exact calculation of the oxygen duration is shown below step by step: Step 1- Evaluation of the Oxygen cylinder pressure The actual oxygen cylinder pressure is indicated on the oxygen pressure gauges, one installed on the upper right hand side of the instrument panel and the other installed in the oxygen compartment next to the filler port. Resultant of this pressure the oxygen pressure variable Po can be calculated: 1850 200 Pr PSI essure PO − = DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-19 Step 2- Evaluation of the individual oxygen mass flow The individual mass flow depends on the type of the dispensing equipment and on the expected main flight altitude: Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-20 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E The figure mentioned above and the table below shows the required mass flow depending on the flight altitude and the used dispensing equipment: Main flight altitude Mass flow [l/min] Oxysaver cannula Mass flow [l/min] Mask or regular/ standard cannula 10.000ft 0,25 0,80 11.000ft 0,31 0,92 12.000ft 0,37 1,04 13.000ft 0,43 1,16 14.000ft 0,48 1,28 15.000ft 0,53 1,40 16.000ft 0,59 1,52 17.000ft 0,65 1,64 18.000ft 0,70 1,76 The mass-flow-variable Fm is calculated as shown below: 4 3 2 1 1 User User User User Fm + + + = “User X” is the required individual mass flow according to the chart / diagram mentioned above. Step 3- Final calculation Finally the oxygen duration is calculated as shown below: ] [ 6 , 23 hours duration F P m o = DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-21 Example: Oxygen pressure: 1650 PSI Expected flight altitude: 16.000ft Number of persons on board: 3 Used dispensing equipment: 2x Oxysaver cannulas , 1 x Mask Step 1: 784 , 0 1850 200 1650 = − = PSI PO Step 2: 3704 , 0 52 , 1 59 , 0 59 , 0 1 = + + = m F Step 3: h 9 , 6 6 , 23 3704 , 0 784 , 0 = Result: The oxygen system is able to supply 6,9 h supplemental oxygen to the occupants in 16.000ft. After 6,9h 200 PSI will be left in the oxygen cylinder. Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-22 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E 6. MASS AND BALANCE 6.4 FLIGHT MASS AND CENTER OF GRAVITY 6.4.1 MOMENT ARMS The most important lever arms aft of the Datum Plane: Item Lever Arm [m] [in] Oxygen cylinder 0.82 32.3 6.4.3 CALCULATION OF LOADING CONDITION When operating the airplane near the forward flight mass CG limit, note that a full oxygen tank shifts the CG approximately 2 mm (0.08 in) forward. DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-23 7. DESCRIPTION OF THE AIRPLANE AND ITS SYSTEMS 7.15 OXYGEN SYSTEM 7.15.1 GENERAL A four-place oxygen system provides the supplementary oxygen necessary for continuous flight at high altitude. An oxygen cylinder is located in the center section of the forward baggage compartment, in its own enclosed, vented compartment. A combined pressure regulator/shutoff valve attached to the cylinder automatically reduces pressure to the delivery pressure required for the operating altitude. The oxygen cylinder filler valve is located on the LH side of the oxygen compartment next to the cylinder in the forward baggage compartment. The 50 cubic feet (1.41 cubic meters) capacity oxygen cylinder may be filled to 1850 psi while installed in the airplane and has a pressure gauge located next to the filler valve to indicate the amount of oxygen in the cylinder. An identical gauge is located on the upper RH side of the instrument panel (above the circuit breaker panel). The oxygen supply shut-off control is located on the LH side below the instrument panel. It is cable connected to the oxygen regulator valve, controlling the oxygen system by pulling the green control knob out for “ON” and pushing the same knob in for system supply “OFF”. The system should be left “OFF” when not in use. Four (4) oxygen ports, two forward and two aft, are located in positions convenient to all four occupants. These ports are serviced directly from the oxygen cylinder. The oxygen ports are located (1 each) in the map pocket recess for the pilot and co- pilot. The passenger oxygen ports are located overhead in the “roll-over bar” next to the cabin speaker. The individual cannula or mask supply tubes are plug-in connected to each port and contain the individual flow adjustments (flow meter-needle valve) for each occupant. Note that these ports are serviced directly from the oxygen regulator valve. Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-24 09-Mar-2021 Rev. 2 Doc. # 7.01.06-E It is the pilot’s responsibility to instruct each passenger in the use of this oxygen system prior to flight and to assure that there is adequate and comfortable supply of oxygen aboard for each occupant. The oxygen cylinder, when fully charged, contains 50 cubic feet (1.41 cubic meters) of aviator’s breathing oxygen under a pressure of 1850 psi at 21 °C (70 °F). Filling pressures will vary due to the ambient temperatures in the filling area and the rise of temperature resulting from the compression of the oxygen. Due to these factors merely filling the cylinder to 1850 psi will not result in a properly filled cylinder. Fill oxygen cylinders to the pressures indicated in the table shown below, based of the filling area’s ambient temperature. The oxygen system is limited to 1850 psi at 21°C (70 °F) ambient temperature. WARNING Oil, grease or other lubricants in contact with oxygen creates a serious hazard. Such contact must be avoided when handling oxygen equipment. Ambient Temperature °C (°F) Max. Filling Pressure [psi] Ambient Temperature °C (°F) Max. Filling Pressure [psi] -18 (0) 1515 16 (60) 1800 -12 (10) 1565 21 (70) 1850 -7 (20) 1610 27 (80) 1900 -1 (30) 1660 32 (90) 1945 4 (40) 1705 38 (100) 1995 10 (50) 1755 42 (110) 2040 DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-25 7.15.2 USE OF CANNULAS AND MASKS Attachment and adjustment a) Standard cannulas b) Oxysaver® cannulas – Pendant model Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-26 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E c) Oxysaver® cannulas 1. Slide the loop adjustment collar (bola) down to enlarge the size of the loop: 2. With the back of the facepiece toward you, pick up the Oxysaver with one of the small flexible plastic tubes in each hand, as if putting on eyeglasses: DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-27 3. Place the flexible plastic tubing over your ears (as if putting on glasses) and under your chin or pass the tubing over your ears and around the back of your head: 4. The facepiece should rest on you upper lip under you nose, with the oxygen delivering prongs extending well into and pointing towards the back of your nose. You may rotate these prongs for maximum comfort. 5. Slide the bola up toward your chin to hold the cannula snugly and comfortably against your face. 6. Screw the brass hose tip onto the manifold NOTE The use of each Oxysaver cannula system is to be logged by the hour and the system replaced with a new unit at 200 hours of use! Use the LOG delivered with each Oxysaver cannula. Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-28 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E c) Masks 1. Remove the rubber band from the reservoir bag and allow it to deploy. 2. Attach Aerox flowmeter to the oxygen hose of mask and then to the oxygen system. NOTE The reservoir bag must be in good condition and inflated before use! 3. Position the bottom of the mask as low as possible under the chin while positioning the narrow portion of the mask on the bridge of the nose. 4. Position the cradle above the ears so that it straddles the crown of the head. 5. Hook the lower headband straps below the ears and around the back of the neck. 6. Adjust the upper headband by pulling both straps at the same time. 7. Adjust the lower headband straps in the same manner. 8. Remove the mask to adjust the straps. 9. Do not over-tighten the straps. NOTE Return mask to Aerox for service 3 years from manufacture date. Manufacture date code is located on the re-breather bag. DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-29 10. Plug in the microphone plug in the applicable microphone jack (type: MSK-AEM only) d) Flowmeter installation/adjustment 1. Connect the flowmeter between the cannula /mask tube (outlet) and the delivery hose (inlet). NOTE When assembling the tube to the flowmeter, only push the tube as far as the second ferrule. 2. Connect the cannula/mask assembly to the assigned outlet manifold. 3. Hold the flowmeter in vertical position and turn the needle valve screw installed on the connector counterclockwise. Adjust flowrate to current altitude by using the correct flowmeter scale. NOTE For regular / “standard”- cannulas the “MASK” scale must be used. Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-30 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E CAUTION Failure to use appropriate scale will result in incorrect oxygen consumption. NOTE When adjusted to the correct altitude the dispensing unit will deliver enough supplemental oxygen as required by “normal” people. Some people will require more oxygen. In that case adjust the flowmeter to a higher altitude. 4. Check flowmeter regularly to ensure adequate flow. 7.15.3 APPROVED OXYGEN The AEROX continuous oxygen system uses aviator’s breathing oxygen in accordance with MIL-PRF-27210 only. CAUTION Do not use oxygen with a lower purity grade than prescribed by MIL-PRF-27210. CAUTION The oxygen cylinder is limited to a pressure of 1850 psi at 21°C (70 °F) ambient temperature.. DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-31 7.15.4 APPROVED DISPENSING EQUIPMENT Type Description Man. CC Conserving cannula Oxysaver brand (adult) AEROX CC-P Conserving cannula Oxysaver brand (adult) pendant AEROX CR-A Cannula regular style (adult)/ “standard”- cannula AEROX CR-C Cannula regular style (child)/ “standard”- cannula AEROX MSK-AS Silicone mask without microphone, (Quick Donning Type) AEROX MSK-AEM Silicone mask with microphone, (Quick Donning Type) AEROX NOTE Each cannula and mask must be equipped with a Puritan Bennett style connector and an Aerox flowmeter (type: FM or FMNV) NOTE The Aerox oxygen system, installed in the DA 42 must not be used with any other dispensing equipment. NOTE There must be 4 cannulas (or at least one for each occupant) and 1 mask (type: MSK-AEM) on board. The cannulas and masks must be accessible during flight. Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-32 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E 8. AIRPLANE HANDLING, CARE AND MAINTENANCE The cannulas and masks can be cleaned with soap and water using a clean, lint-free cloth. 8.4 SERVICING 8.4.5 REPLENISHMENT OF THE CYLINDER CAUTION Do not carry flammable fluids, oils and greases, in the nose baggage compartment! CONTINUED 1. Oxygen gauge (instrument panel) ...... check 2. LH front baggage door ........................ open WARNING Do not smoke during refilling! 3. Baggage compartment ........................ all items removed 4. Baggage compartment ........................ check for oil or oil residue WARNING Oxygen in conjunction with oil will result in a fire hazard! CONTINUED DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Continuous Flow Oxygen System Doc. # 7.01.06-E 10-Nov-2011 Rev. 1 Page 9-S04-33 5. De-icing fluid tank ................................ check, closed and clean 6. Refill cover .......................................... open 7. Refill valve cover .................................. open 8. Oxygen gauge (refill panel) .................. checked, same pressure as indicated on instrument panel gauge 9. Filling station outlet port ....................... connect 10. Filling station outlet port ....................... check fixed Slightly open the cylinder valve of the filling station and check oxygen flow. The oxygen cylinder is limited to a pressure of 1850 psi at 21°C (70 °F) ambient temperature. WARNING Do not fill the cylinder to a pressure above 1850 psi at 21°C (70°F) ambient temperature. NOTE Refilling of a fully depleted cylinder will take about 3.5 minutes. when the pressure is reached: 11. Filling station valve ............................... close 12. Filling station outlet port ....................... disconnect slightly 13. Refill valve cover .................................. fixed 14. Refill cover ........................................... close 15. Baggage compartment......................... close, as required END OF CHECKLIST Continuous Flow Oxygen System DA 42 AFM with OÄM 42-102 Garmin GFC 700 Supplement S04 Page 9-S04-34 10-Nov-2011 Rev. 1 Doc. # 7.01.06-E Intentionally left blank.