Schedule Of Airworthiness Directives

Cessna 550 Citation II · Service Bulletins · 1990 · 1 page · 11 KB

Service Bulletins for the Cessna 550 Citation II

PDF, 1 page, 11 KB, from Sprinkle’s own files.

What it covers

This document is a Service Bulletin issued by the Civil Aviation Safety Authority of Australia, specifically addressing airworthiness directives for the Cessna 550 (Citation II) series aircraft. It outlines critical safety measures that must be taken regarding the freon air conditioning system and elevator control cables. The bulletin is aimed at operators and maintenance personnel of the Cessna 550, 551, and S550 series aircraft fitted with specific air conditioning systems. Compliance with the directives is essential to ensure the continued airworthiness and safety of the aircraft, particularly in preventing potential control loss due to reported defects.

Key points

  • Deactivate the air conditioning system by pulling circuit breakers and securing them with tie wraps before further flight.
  • Inspect elevator control cables in the aft baggage compartment for damage within 10 hours of service after April 18, 1990.
  • Replace mounting hardware on the inboard rail and the existing earth wire as per Kieth Service Bulletin 108 before reactivating the air conditioning system.
  • Failure to comply with these directives could lead to loss of control of the aircraft due to damaged elevator control cables.
  • The directives apply to Cessna 550, 551, and S550 series aircraft with specific air conditioning systems.

Main sections

Applicability

The directives apply to Cessna 550, 551, and S550 series aircraft equipped with STC SA 2698SW freon air conditioning systems.

Requirements

Operators must deactivate the air conditioning system by pulling the circuit breakers and securing them with tie wraps. A visual inspection of the elevator control cables in the aft baggage compartment is required to check for damage from arcing or chafing. Additionally, mounting hardware on the inboard rail must be replaced, and the existing earth wire should be replaced as per Kieth Service Bulletin 108.

Compliance

The compliance timeline specifies that the air conditioning system must be deactivated before further flight after April 18, 1990. The visual inspection of elevator control cables must be completed within 10 hours of service after the same date, and the air conditioning system must not be reactivated until the necessary replacements are made.

Background

The bulletin was issued following reports of arcing from the freon air conditioning unit, which has caused damage to elevator control cables. This defect poses a significant risk, potentially leading to loss of control of the aircraft if not addressed.

Safety notes

  • A defect in the air conditioning unit could lead to arcing and damage to elevator control cables, risking loss of control.

The document’s text

Show the text read from the PDF

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY SCHEDULE OF AIRWORTHINESS DIRECTIVES Cessna 550 (Citation II) Series Aeroplanes AD/CESSNA 550/19 Freon Air Conditioner/Elevator Control Cable 7/90 TX Applicability: Model 550, 551 and S550 series fitted with STC SA 2698SW freon air conditioning systems. Requirement: 1. Deactivate the air conditioning system by pulling the airconditioner circuit breakers on the main junction box and install tie wraps to preclude inadvertent re- setting. 2. Visually inspect the elevator control cables under and in the vicinity of the aft baggage compartment floor for evidence of damage caused by either arcing or chafe. 3. Replace mounting hardware on the inboard mounting rail and replace existing earth wire in accordance with Kieth Service Bulletin 108. Note: FAA Emergency AD 90-07-10 refers. Compliance: 1. Prior to further flight after 18 April 1990. 2. Within 10 hours time in service after 18 April 1990. 3. Prior to reactivating the airconditioning system. Background: There has been a report of arcing from the freon airconditioning unit that has burned through an elevator control cable. A defect, if uncorrected, could lead to loss of control. -- 1 of 1 --

Read from the PDF by machine, so tables and diagrams come out rough. The PDF is the document.

More Cessna 550 Citation II documents

All 32 →

Cessna 550 for sale now

View all 92 for sale →

Aircraft that this service bulletins covers, listed on the sites Sprinkle reads. Asking prices, not sales. Cessna 550 asking prices by year built.

Also useful for the Cessna 550 Citation II

From Sprinkle’s library of aircraft documents. PDFs open from Sprinkle’s own files. Read Mar 10, 2026.

Want this document taken down? Request removal