Skip to content

Service Bulletin

Eurocopter AS350BA · Service Bulletins · 2002 · 199 KB

Service Bulletins for the Eurocopter AS350BA

PDF, 199 KB, from Sprinkle’s own files.

What it covers

This document is a mandatory service bulletin for all AS350 helicopter owners/operators, detailing the relocation of the bypass door power circuit. It outlines compliance requirements, installation instructions, and necessary revisions to the flight manual.

Key points

  • Mandatory service bulletin for AS350 helicopters.
  • Relocation of bypass door power circuit is required.
  • Compliance must be completed within 60 hours of flight time or 60 days.
  • Installation time is estimated at 1 man-hour.
  • Weight and balance are not affected by this modification.
  • Functional checks are required after installation.
  • Log book entry is necessary upon completion.
  • Refer to the AS350 Maintenance Manual for detailed instructions.

Main sections

Background

The bulletin addresses the relocation of bypass door circuit power for commonality.

Compliance

This is a mandatory service bulletin that must be complied with.

Installation Instructions

Detailed steps for relocating the power circuit and performing functional checks are provided.

Compliance Time

The modification must be completed within 60 hours of flight time or 60 days, whichever comes first.

Flight Manual Revision

A revision to RFMS 1350-1200 is required after compliance.

Log Book Entry

A maintenance entry must be made in the log book upon completion of the modification.

The document’s text

Show the text read from the PDF

8 Digital Drive Suite 104, Novato, CA 94949, USA Phone 415-884-0555 Fax 415-884-0505 Page 1 of 5 SERVICE BULLETIN TO : All AS350 Owners/Operators FROM : FDC/aerofilter Engineering SB NUMBER : SB.FDC.AS350.0002 ORIGINAL SB NO. : SB AS350-02 CATEGORY : Mandatory Service Bulletin EFFECTIVITY : AS350 Helicopters 1 equipped with Engine inlet Air Filter System per STC SR00811SE or SR01049SE (FDC P/N 1350IN1-1, -7 or -9; S/N: 1 thru 77) DATE : August 28, 2002 Relocation of Bypass Door Power 1.0 BACKGROUND Relocation of bypass door circuit power from 1350A11-11 Panel Assembly to PP6 fuse panel with other circuit protective devices for commonality. 2.0 COMPLIANCE Mandatory Service Bulletin 3.0 COMPLIANCE TIME 1. Within 60 hours flight time OR 2. 60 days Whichever comes first 4.0 SPARES KIT AVAILABILTY None applicable 1 Model Engine Installation D, D1 Lycoming LTS-101-600A-2 Factory D Lycoming LTS-101-600A-3 STC SH5815SW D Lycoming LTS-101-600A-3A STC SR00772SE BA Lycoming LTS-101-600A-3A STC SR00772SE or STC SR00805SE B, B1, B2, BA, B3 Turbomeca Arriel Factory -- 1 of 5 -- 8 Digital Drive Suite 104, Novato, CA 94949, USA Phone 415-884-0555 Fax 415-884-0505 Page 2 of 5 5.0 INSTALLATION TIME Est. 1 man-hour. 6.0 WEIGHT & BALANCE Not affected 7.0 FLIGHT MANUAL REVISION Yes. RFMS 1350-1200 revision C or later FAA approved revision per STC SR00811SE or SR01049SE. 8.0 DOCUMENTS None 9.0 INSTALLATION INSTRUCTIONS Refer to the applicable Eurocopter AS350 Maintenance Manual, Wiring Diagram Manual and Parts Catalog as required to comply with this Service Bulletin A. MODIFICATION (1) Remove power from aircraft. (2) Gain access to Fuse Panel and BUSBAR PP6, refer to Figure 1. (3) Identify fuse location No. 782 and install one (1) standard Eurocopter 2.5 AMP Fuse3 . (4) Identify and mark 2.5 AMP fuse as “ENG ALT AIR POWER” using DECAL P/N 1350E1-201. (5) Relocate wire 3509A20 to connection strip 27∆ 22 terminal 15 associated with fuse installed in step 3 (Reference AS350 Wiring Diagram Manual Chapter 39 and Figure 1). (6) Close panel per AS350 Maintenance Manual. B. FUNCTIONAL CHECK (1) Ensure “ENG ALT AIR” switch on Panel Assembly is in guarded position (CLOSED). 2 If this fuse location is unavailable, use next available location and associated connection strip and terminal. Reference AS350 Wiring Diagram Manual Chapter 39. 3 Eurocopter P/N: D1-2-5. -- 2 of 5 -- 8 Digital Drive Suite 104, Novato, CA 94949, USA Phone 415-884-0555 Fax 415-884-0505 Page 3 of 5 (2) Apply power to aircraft. (3) Reset “ENG ALT AIR” circuit breaker on Panel Assembly. (4) Set Engine Alternate Air Switch to OPEN. (5) Verify that both bypass doors fully open. (6) Set Engine Alternate Air Switch to CLOSE. (7) Verify that both bypass doors fully close. (8) Turn on instrument lights and ensure that post lights function properly on bright and dim. (9) This completes the functional check. C. LOG BOOK ENTRY (1) Upon completion of this modification, make an appropriate maintenance entry in the log book similar to “Accomplished FDC Service Bulletin No. AS350.0002 on (date) by (name), number/stamp.” -- 3 of 5 -- 8 Digital Drive Suite 104, Novato, CA 94949, USA Phone 415-884-0555 Fax 415-884-0505 Page 4 of 5 Figure 1 – Fuse Panel and Busbar PP6 Wiring for Inlet Air Filter System FDC Engineering Russell Goulden Vice President -- 4 of 5 -- 8 Digital Drive Suite 104, Novato, CA 94949, USA Phone 415-884-0555 Fax 415-884-0505 Page 5 of 5 SERVICE BULLETIN COMPLIANCE NOTIFICATION SB.FDC.AS350.0002 TO : FDC Engineering FROM : COMPANY : AIRCRAFT : S/N(s) PHONE : FAX : EMAIL : DATE : I have fully complied with FDC SB.FDC.AS350.0002 NAME : POSITION : A&P NO : DATE : SIGNED : ................................................... MAIL TO : FDC Engineering Filtration Development Company LLC 8 Digital Drive, Suite 104. Novato, California 94949 OR EMAIL : SBFDCAS3500002@fdcaerofilter.com OR FAX : 415-884-0505 -- 5 of 5 --

Read from the PDF by machine, so tables and diagrams come out rough. The PDF is the document.

More Eurocopter AS350BA documents

All 3 →

Airbus Helicopters 350 for sale now

View all 69 for sale →

Aircraft that this service bulletins covers, listed on the sites Sprinkle reads. Asking prices, not sales. Airbus Helicopters 350 asking prices by year built.

Also useful for the Eurocopter AS350BA

From Sprinkle’s library of aircraft documents. PDFs open from Sprinkle’s own files. Read Sep 18, 2026.

Want this document taken down? Request removal