RFID Specifications
CESSNA 185 · Specifications
Overview
This document provides detailed specifications for the RFID system, specifically designed for industrial applications. It includes information on various transceivers, tags, and their compatibility with the ISO 15693 standard. The document is intended for engineers and technicians involved in the implementation and maintenance of RFID systems. Key features include the types of transceivers available, their operational parameters, and environmental specifications, ensuring users can effectively integrate these systems into their existing architectures.
- The RFID system operates at a frequency of 13.56 MHz.
- Transceivers can be mounted up to 91.4 m (300 ft) away from the interface module.
- Tags are available in various sizes, including 8 mm to 50 mm in diameter.
- The system is compliant with ISO 15693 standards for high-frequency RFID.
- Operating temperature range for devices is -40 °C to +85 °C.
Document
Source
Originally published by literature.rockwellautomation.com. Sprinkle hosts a reference copy with an added summary, specifications and searchable full text.
Document details
- Type
- Specifications
- Year
- 2019
- Pages
- 30
- File size
- 2.5 MB
- Publisher
- literature.rockwellautomation.com
Common. Rarer than 1% of the aircraft models we track.
Most owners only have the POH. Here's the essential set for the CESSNA 185.
- Pilot's Operating Handbook / AFM
- Checklist
- Maintenance Manual
- Parts Catalog (IPC)
- Systems & Wiring
- Service Bulletins
- Type Certificate (TCDS)
CESSNA 185 for sale now
Free — save the 185 to your watchlist and track it in one place.
More CESSNA 185manuals & documents
See all 40 →- Service Bulletin No. SB24-01 | Aircraft SpruceService Bulletins
- Cessna 185 Training ManualTraining Manual
- Ethernet Media Specifications Technical DataSpecifications
- Weight & Balance - ForeFlightWeight And Balance
- SUPERVISORY HANDBOOK ON THE VALIDATION OF IRB RATING SYSTEMSOther Documents
- PARTS MANUAL 4000 FLOATS ON CESSNA 185 & 206 SERIESAvionics Manual
- MICRO SWITCH V15 Series Basic Switch DatasheetSpecifications
- Airworthiness Approval of Synthetic Vision SystemsAdvisory Circular
- SERVICE MANUAL FOR THE WIPLINE MODEL 4000 AMPHIBIOUS ...Maintenance Manual
- Airplane Flight Manual Supplement Revision ListFlight Manual
- INSTALLATION INSTRUCTIONS SUPPLEMENTAL TYPE CERTIFICATE SA04491CHFlight Manual
- COST-EFFECTIVE RADIO COMMUNICATIONSpecifications
If you fly the CESSNA 185, you may also be researching these.
In this document
Summary of Changes
This section outlines the removal of Bulletin 57RF handheld interfaces from the publication due to product obsolescence.
High-frequency EtherNet/IP Interface Block
Describes the EtherNet/IP interface block designed for high-frequency RFID applications. It supports networking and allows for multiple read/write points, with local status indicators for quick diagnosis.
Transceivers
Details various types of transceivers including cylindrical, square, and rectangular options. Each type has specific dimensions, operational ranges, and compatibility with different tags.
Tags
Discusses the different types of RFID tags available, including their memory sizes, operating frequencies, and environmental specifications.
Environmental Specifications
Lists the operational and storage temperature ranges, humidity tolerances, and shock resistance ratings for the RFID components.
Full document text
Technical Data RFID Specifications Bulletin Number 56RF Our Bulletin 56RF High-frequency Radio Frequency Identification (RFID) system is ideal to track and document products as they move through the manufacturing process in light-duty industrial applications. The RFID system tags and transceivers are designed to the ISO 15693 open standard for high frequency. Topic Page Summary of Changes 2 High-frequency EtherNet/IP Interface Block 3 Transceivers 18 mm and 30 mm Cylindrical Transceiver 9 Square 40 x 40 mm Transceiver 12 Rectangular 80 x 90 mm Transceiver 14 Status Indicator Illumination Pattern 16 Transceiver Cordsets and Patchcords 16 Connector Pinout 16 Tags Disc Tag — ICODE SLI, SLIx, and SL2 Memory 17 Disc Tag — ICODE FRAM Memory 21 Disc Tag — ICODE Large FRAM Memory 23 Paper Tag — ICODE SLIx and SLI Memory 24 Proximity ISO Card — ICODE SLI Memory 27 High-temperature Tag Testing 28 2 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications Summary of Changes Bulletin 57RF handheld interfaces have been removed from this publication due to product obsolescence. Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 3 RFID Specifications — High-frequency EtherNet/IP Interface Block High-frequency EtherNet/IP Interface Block The EtherNet/IP interface block is designed to solve industrial high frequency 13.56 MHz RFID applications that require networking or multiple read/write points. Local status indicators allow for quick visual diagnosis of module status, network status, I/O status, and power status. Each interface block can have up to two transceivers and two general I/O devices, which allows the RFID system to be easily integrated into an existing architecture. This configuration also allows the RFID system to respond to sensor input and vice versa. For example, a sensor can detect the presence of an object and send a signal to the transceiver to read the RFID tag. The high frequency 13.56 MHz RFID system is also highly configurable and expandable. The transceivers can be mounted up to 91.4 m (300 ft) away from the interface blocks. The EtherNet/IP ports are configured as an embedded switch with Device Level Ring (DLR), which allows multiple interface blocks to be connected in star, tree, linear, and ring topologies. The RFID system is ISO 15693 compliant and compatible with tags of many different styles and sizes. Product Selection Table 1 - Transceiver Interface Port (1) (1) Configured as embedded switch. Supports star, tree, linear, and ring topologies. Inputs Outputs Cat. No. 1 transceiver 1 1 56RF-IN-IPS12 2 transceivers 1 1 56RF-IN-IPD22 2 transceivers 2 — 56RF-IN-IPD22A Table 2 - Interface Block Cables Interface Connector Style Connector Type No. of Pins Shielding Wire Size (AWG) Cat. No. Transceiver DC Micro (M12) patchcord Straight female to straight male 4 Shielded 22 889D-F5FCDM-Jx(1) (1) Replace x with 0M3 [0.3 m (11.8 in.)], 1 [1 m (3.3 ft], 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (33 ft)] for standard cable lengths. DC Micro (M12) cordset Straight female 889D-F5FC-Jx(2) (2) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (33 ft)] for standard cable lengths. Straight male 889D-M5FC-Jx(2) M12 terminal chamber Straight female — 18…22 871A-TS5-D1 Straight male 871A-TS5-DM1 Auxiliary power DC Micro (M12) patchcord Straight female to straight male 4 Unshielded 22 889D-F4ACDM-x(1) DC Micro (M12) cordset Straight female 889D-F4AC-x(2) Straight male 889D-M4AC-x(2) M12 terminal chamber Straight female — 871A-TS4-D Straight male 871A-TS4-DM EtherNet/IP M12 D-code patchcord Straight male to straight male 4 Shielded 26 1585D-M4UBDM-x(3) (3) Replace x with OM3 [0.3 m (11.8 in.)], OM6 [0.6 m (23.6 in.)], 1 [1 m (3.3 ft)], 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], 10 [10 m (33 ft)], 15 [15 m (49 ft)], and increments of 5 m (16.4 ft) up to 75 m (246 ft). Straight male to right angle male 1585D-M4UBDE-x(3) Right angle male to right angle male 1585D-E4UBDE-x(3) Straight male to straight male Unshielded 24 1585D-M4TBDM-x(3) Straight male to right angle male 1585D-M4TBDE-x(3) Right angle male to right angle male 1585D-E4TBDE-x(3) 4 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — High-frequency EtherNet/IP Interface Block Specifications Table 3 - Input Table 4 - Output Table 5 - RFID Specifications Attribute 56RF-IN-IPS12, 56RF-IN-IPD22, and 56RF-IN-IPD22A Number of transceiver inputs 2 – 56RF-IN-IPD22 and 56RF-IN-IPD22A 1 – 56RF-IN-IPS12 Number of standard inputs 2 – 56RF-IN-IPD22A 1 – 56RF-IN-IPD22 and 56RF-IN-IPS12 Standard input type Sink, 24V DC Voltage, off-state input, max 5V DC Voltage, on-state input, max 30V DC Voltage, on-state input, nom 24V DC Voltage, on-state input, min 11V DC Current, off-state input, max 1.5 mA @ 5V DC Current, on-state input, max 5 mA @ 30V DC Voltage, sensor source, max 30V DC Voltage, sensor source, min 10V DC Input delay time ON to OFF OFF to ON 0…16000 <Symbol>m<Symbol>s Isolation voltage 50V (continuous), basic insulation type, inputs and sensor power to network No isolation between individual Inputs or between network channels Type tested at 707V DC for 60 s Attribute 56RF-IN-IPS12 and 56RF-IN-IPD22 Number of standard outputs 1 Standard output type Source, 24V DC Voltage drop, on-state output, max 0.5V DC Voltage off-peak blocking, min 30V DC Voltage, on-state output, max 30V DC Voltage, on-state output, min 11V DC Voltage, on-state output, nom 24V DC Current on-state output, max 0.5 A Leakage current, off-state output, max 50 <Symbol>m<Symbol>A Surge current per output, max 1.2 A for 10 ms, repeatable every 2 s Isolation voltage 50V (continuous), basic insulation type, outputs, and output power to network No isolation between individual outputs or between outputs and output power or between network channels Type tested at 707V DC for 60 s Attribute 56RF-IN-IPS12 and 56RF-IN-IPD22
Show full textShow less
Voltage 24V DC (-20…+10%) Output current per RFID port, max 100 mA @ 24V DC Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 5 RFID Specifications — High-frequency EtherNet/IP Interface Block Table 6 - General Specifications Attribute 56RF-IN-IPS12, 56RF-IN-IPD22, and 56RF-IN-IPD22A Voltage, auxiliary power(1) (1) Intended for limited voltage power, limited current supply. 24V DC (-20…+10%) Auxiliary current per module, max(2) (2) A listed or recognized 4 A fuse must be installed on the line side of the device. 4 A Output current per RFID transceiver port, max 100 mA @ 24V DC Current for output device power per I/O port, max 0.5 A @ 30V Current for input device power per I/O port, max 5 mA @ 30V Communication rate EtherNet/IP 10/100 Mbps Full or half-duplex 100 meter per segment Status indicators Module Status - red/green Network Status - red/green Link Status - green/yellow Auxiliary Power - green I/O Status Indicator - yellow Dimensions (H x W x D), approx 179 x 37 x 43.25 mm (7.05 x 1.46 x 1.7 in.) Weight, approx 0.2 kg (0.45 lb) Enclosure type rating IP67 and IP69K Wiring category (3) (3) Use this conductor category information for planning conductor routing. See publication 1770-4.1, Industrial Automation Wiring and Grounding Guidelines. 1 - on signal ports 1 - on power ports 1 - on communication ports 6 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — High-frequency EtherNet/IP Interface Block Table 7 - Environmental Specifications Attribute 56RF-IN-IPS12, 56RF-IN-IPD22, and 56RF-IN-IPD22A Temperature, operating IEC60068-2-1/2, Test Ad/Bd Cold: -20 °C (-4 °F) Dry Heat: 60 °C (140 °F) Gradient: 1 °C (33.8 °F)/min Duration: 33.6 hr with insulation tests Temperature, storage IEC60068-2-1/2, Test Ad/Bd Cold: -40 °C (-40 °F) Dry Heat: 85 °C (185 °F) Gradient: 1 °C (33.8 °F)/min Duration: 33.6 hr with insulation tests Relative humidity IEC60068-2-30, Test Db Temperature Cycle Range: 20-60-20 °C (68-140-68 °F) Humidity Cycle Range: 80…95% noncondensing Vibration IEC60068-2-6 Frequency Range: 10…500 Hz Acceleration: 5 g Displacement: 0.030 in. (p-p) Duration: One octave per minute sweep rate No. of sweeps: 10 Vertical mounting Shock, operating IEC60068-2-27 Acceleration: 30 g, 11 ms Vertical mounting Shock, nonoperating IEC60068-2-32, Test Ea Acceleration: 50g, 11 ms Vertical mounting Emissions IEC61000-6-4 (CISPR11) Class A ESD susceptibility (Performance Criteria B) IEC61000-4-2 Indirect (Coupling Plate): +/-6 kV contact discharge Direct (to “Points of Initial Contact”): +/-6 kV contact discharge; +/-8 kV air discharge Radiated RF immunity (Performance Criteria A) IEC61000-4-3, ENV50204 80…1000 MHz: 10V/m, with 1 kHz sine-wave 80% AM 1…2 GHz: 10V/m, with 1 kHz sine-wave 80% AM 900 MHz Pulse: 10V/m, with 200 Hz 50% pulse 100% AM 1.89 GHz Pulse: 10V/m with 200 Hz 50% pulse 100% AM 2…2.7 GHz: 1V/m, with 1 KHz sine-wave 80% AM EFT/B immunity (Performance Criteria B) IEC61000-4-4 DLR Ports: +/-3 kV clamp inject at 5 kHz for 5 min Module and Output Power: +/-3 kV clamp inject at 5 kHz for 5 min Digital I/O: +/-3 kV clamp inject at 5 kHz for 5 min Analog I/O: +/-3 kV clamp inject at 5 kHz for 5 min Earth Ground: +/-3 kV clamp inject at 5 kHz for 5 min Surge immunity (Performance Criteria B) IEC61000-4-5 DLR Ports: +/-2 kV common mode @ 2 ohms Module and Output Power: +/-2 kV common mode @ 12 ohms; +/-2 kV differential mode @ 2 ohms Shielded Digital I/O: +/-2 kV common mode @ 2 ohms Shielded Analog I/O: +/-2 kV common mode @ 2 ohms Conducted Radiated Immunity (Performance Criteria A) DLR Ports, Module Power, Output Power, Digital I/O, and Analog I/O 150 kHz…80 MHz, CDN inject 10V, with 1 kHz sine-wave 80% AM Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 7 RFID Specifications — High-frequency EtherNet/IP Interface Block Table 8 - Compliance Pinouts Compliance (When Product is Marked)(1) (1) See the Product Certification webpage (rok.auto/certifications) for Declarations of Conformity, Certificates, and other certification details. Value CE European Union 2004/108/EC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) EtherNet/IP ODVA conformance tested to EtherNet/IP specifications. EtherNet/IP Power Connector RFID Transceiver Interface Input Connector Output Connector Connector Diagram Pin Function Function Function Function Function 1 TX+ Output Power + Sensors Power + Sensor Power Not Used 2 RX+ Module Power + Data+ Not Used Not Used 3 TX- Module Power - Sensor Power - Return Return 4 RX- Output Power - Data - Input Output 5 Shell — Shield/FE Shield/FE Shield/FE 3 2 1 4 4 3 1 2 5 4 3 1 2 5 4 3 1 2 5 4 3 1 2 8 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — High-frequency EtherNet/IP Interface Block Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 1 - Interface Block Dimensions 37 (1.46) 179 (7.05) 169 (6.64) 43.25 (1.7) 19.8 (0.78) 166.5 (6.56) 27 (1.06) Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 9 RFID Specifications — Transceivers Transceivers We offer cylindrical, square, and rectangular transceivers to meet the requirements of your application. 18 mm and 30 mm Cylindrical Transceiver Our cylindrical transceivers are designed for use with the Allen-Bradley® high frequency 13.56 MHz RFID system. These transceivers are ISO 15693 compliant and can read/write ICODE tags SLI and SL2, which allows for infinite tag configuration options from various manufacturers. Local status indicators allow for quick visual diagnosis of module status and read/write status. These transceivers are recommended for panel mounting and for use with smaller tags with a diameter of 10…30 mm (0.39…1.18 in.). Transceivers can be mounted up to 91.4 m (300 ft) away from the interface module. M18 transceivers can read tags from distances up to 55 mm (2.2 in.), while M30 transceivers can read tags up to 75 mm (3.0 in.). These transceivers have an enclosure rating of IP67 and are designed to withstand harsh industrial environments. Product Selection Specifications Table 9 - Transceiver Description Cat. No. M18 cylindrical transceiver 56RF-TR-M18 M30 cylindrical transceiver 56RF-TR-M30 Table 10 - Mounting Bracket Description Transceiver Cat. No. Swivel/tilt style M18 60-2649 M30 60-2439 Right angle style M18 871A-BRN18 M30 871A-BRN30 Attribute 56RF-TR-M18 56RF-TR-M30 Supply voltage 24V DC Current consumption, max 100 mA Tag compatibility ICODE tags SLI, SL2, SLIX ISO 15693/ISO 18000-3 M1 ICODE tags SLI, SL2 ISO 15693/ISO 18000-3 M1 Connector M12, 4-pin male Communication systems Half-duplex communication system (RS-485) Communication rate (host) 9600/19,200/38,400/115,200 bps Frequency 13.56 MHz Communication rate (tag) 26.48 Kbps Data length 8 bit Temperature, operating -25…+70 °C (-13…+158 °F) Temperature, storage -40…+85 °C (-40…+185 °F) Operating humidity (noncondensing) 35…95% RH Storage humidity (noncondensing) 25…85% RH Vibration 10 g at 10…500 Hz Shock resistance 50 g Enclosure rating IP67 Material PBT and nickel-plated steel Recommended sensing distance (1) (1) Range reference for a 50 mm (2.0 in.) diameter tag 30 mm (1.18 in.) 45 mm (1.77 in.) Sensing distance, max(1) 55 mm (2.16 in.) 75 mm (3 in.) Distance from interface module, max 91.4 m (300 ft) Compliance CE 10 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Transceivers Minimum Distances Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 2 - Minimum Distance Dimensions Scanning Area Figure 3 - M18 Cylindrical Transceiver Scanning Area Figure 4 - M30 Cylindrical Transceiver Scanning Area > 150 (5.9) > 100 (3.9) Between transceivers, face to face Between transceivers side by side M18: >25 (1.0) M30: >30 (1.2) M18: >25 (1.0) M30: >30 (1.2) Antenna Between transceiver and surrounding metal M18: >150 (5.9) M30: >200 (7.9) M18: >100 (3.9) M30: >160 (6.3) >11 (0.43) IMPORTANT Ideal tag distance for maximum performance is 20…45 mm (0.79…1.77 in.). Referenced to 50 mm (2.0 in.) disc tag. IMPORTANT Ideal tag distance for maximum performance is 30…55 mm (1.2…2.2 in.). Referenced for a 50 mm (2.0 in.) disc tag. Misalignment [mm (in.)] Sensing Distance [mm] 0 45 100 Side Lobe Side Lobe OFF OFF ON OFF 0 -80 (-3.15) -40 (-1.57) 40 (1.57) 80 (3.15) 20 40 60 80 70 30 Misalignment [mm (in.)] Sensing Distance [mm] Side Lobe Side Lobe OFF OFF ON OFF 0 -80 (-3.15) -40 (-1.57) 40 (1.57) 80 (3.15) 0 50 100 30 10 70 90 55 80 60 40 20 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 11 RFID Specifications — Transceivers Tightening Torque Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 5 - Cylindrical Transceiver Approximate Dimensions IMPORTANT Nuts and washers are included. Table 11 - Mounting Nut Torque Transceiver Torque [N•m (ft•lb)] M18 19.8 (14.6) M30 33.9 (25) Nut Washer Read/Write Status LED M18x1 M12x1 Ø16.6 (0.65) 35.8 (1.41) 12.2 (0.48) 63 (2.5) 73 (2.9) 7 (0.28) Ø16.6 (0.65) Module Status LED M18 Cylindrical Transceiver LED 73 (2.9) 63 (2.5) 12.2 (0.48) 35.8 (1.41) 7 (0.28) M30x1.5 M12x1 Ø28 (Ø1.10) Ø28 (Ø1.10) M30 Cylindrical Transceiver 12 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Transceivers Square 40 x 40 mm Transceiver The square transceiver is designed for use with the Allen-Bradley high frequency 13.56 MHz RFID system. This transceiver is ISO 15693 compliant and can read/write ICODE tags SLI and SL2, which allows for infinite tag configuration options from various manufacturers. Local status indicators allow for quick visual diagnosis of module status and read/write status. Square transceivers have universal mounting capability and measure 40 x 40 mm (1.57 x 1.57 in). Transceivers can be mounted up to 91.4 m (300 ft) away from the interface module, and tags are readable from distances up to 85 mm (3.3 in.). This transceiver has an enclosure rating of IP67 and is designed to withstand harsh industrial environments. Product Selection Specifications Description Cat. No. Square 40 x 40 mm transceiver 56RF-TR-4040 Attribute 56RF-TR-4040 Supply voltage 24V DC (-20…+10%) Current consumption, max 100 mA Tag compatibility ICODE tags SLI, SL2 ISO 15693 / ISO 18000-3 M1 Connector M12 4-pin male Communication systems Half-duplex communication system (RS-485) Communication rate (host) 9600/19,200/38,400/115,200 bps Frequency 13.56 MHz Communication rate (tag) 26.48 kbit/s Data length 8 bit Enclosure rating IP67 Temperature, operating -25…+60 °C (-13…+140 °F) Temperature, storage -40…+85 °C (-40…+185 °F) Operating humidity (noncondensing) 35…95% RH Storage humidity (noncondensing) 25…85% RH Vibration 10 g at 10…500 Hz Shock resistance 50 g Recommended sensing distance (1) (1) Range reference for a 50 mm (2.0 in.) diameter tag 50 mm (1.97 in.) Sensing distance, max (1) 85 mm (3.35 in.) Distance from interface module, max 91.4 m (300 ft) Compliance CE, c-UL-us, C-Tick Type of equipment Industrial control Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 13 RFID Specifications — Transceivers Minimum Distances Dimensions that are shown are not intended to be used for installation purposes. Figure 6 - Minimum Distance Dimensions Scanning Area Figure 7 - Square 40 x 40 mm Transceiver Scanning Area Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 8 - Square 40 x 40 mm Transceiver Dimensions Min 300 mm (11.8 in.) Metal Min 30 mm (1.2 in.) Between transceivers From surrounding metal IMPORTANT Ideal tag distance for maximum performance is 30…60 mm (1.2…2.4 in.). Referenced for a 50 mm (2.0 in.) disc tag. Misalignment [mm (in.)] Sensing Distance [mm] 0 100 Side Lobe Side Lobe OFF OFF OFF 0 -80 (-3.15) -40 (-1.57) 40 (1.57) 80 (3.15) 60 30 ON 5.4 (0.21) 12 (0.47) 30 (1.18) 30 (1.18) 46 (1.81) 40 (1.57) 7.5 (0.3) 40 (1.57) 40 (1.57) 73.5 (2.89) 14 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Transceivers Rectangular 80 x 90 mm Transceiver The 80 x 90 mm (3.15 x 3.54 in.) rectangular transceiver is the largest transceiver in the Allen-Bradley high-frequency 13.56 MHz RFID family. This transceiver is ISO 15693 compliant and can read/write ICODE tags SLI and SL2, which allows for infinite tag configuration options from various manufacturers. Local status indicators allow for quick visual diagnosis of module status and read/write status. Rectangular transceivers are recommended for high-speed/high-performance applications because of their large sensing range. Transceivers can be mounted up to 91.4 m (300 ft) away from the interface module, and tags are readable from distances up to 168 mm (6.6 in.). This transceiver has an enclosure rating of IP67 and is designed to withstand harsh industrial environments. Product Selection Specifications Description Cat. No. Rectangular 80 x 90 mm transceiver 56RF-TR-8090 Attribute 56RF-TR-8090 Supply voltage 24V DC (-20…+10%) Current consumption, max 100 mA Tag compatibility ICODE tags SLI, SL2 ISO 15693 / ISO 18000-3 M1 Connector M12 4-pin male Communication systems Half-duplex communication system (RS-485) Communication rate (host) 9600/19,200/38,400/115,200 bps Frequency 13.56 MHz Communication rate (tag) 26.48 kbit/s Data length 8 bit Enclosure rating IP67 Temperature, operating -25…+70 °C (-13…+158 °F) Temperature, storage -40…+85 °C (-40…+185 °F) Operating humidity (noncondensing) 35…95% RH Storage humidity (noncondensing) 25…85% RH Vibration 10 g at 10…500 Hz Shock resistance 50 g Recommended sensing distance (1) (1) Range reference for a 50 mm (2.0 in.) diameter tag 102 mm (4 in.) Sensing distance, max (1) 168 mm (6.6 in.) Distance from Interface Module, max 91.4 m (300 ft) Compliance CE, c-UL-us, C-Tick Type of equipment Industrial control Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 15 RFID Specifications — Transceivers Minimum Distances Dimensions that are shown are not intended to be used for installation purposes. Figure 9 - Minimum Distance Dimensions Scanning Area Figure 10 - Rectangular 80 x 90 mm Transceiver Scanning Area Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 11 - Rectangular 80 x 90 mm Transceiver Dimensions Min 600 mm (23.6 in.) Metal Min 50 mm (2.0 in.) Between transceivers From surrounding metal IMPORTANT Ideal tag distance for maximum performance is 70…130 mm (2.8…5.1 in.). Referenced for a 50 mm (2.0 in.) disc tag. Misalignment [mm (in.)] Sensing Distance [mm] 0 50 100 150 Side Lobe Side Lobe OFF OFF OFF 0 -150 (-5.91) -100 (-3.94) -50 (-1.97) 50 (1.97) 100 (3.94) 150 (5.91) 130 70 ON 170 94 (3.7) 65 (2.56) 65 (2.56) 83 (3.27) 106.5 (4.19) 40 (1.57) 0.2 (0.01) 16 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Transceivers Status Indicator Illumination Pattern Connector Pinout Transceiver Cordsets and Patchcords Status Indicator Display State Status Module status indicator Green light Power on No illumination No power Read/write indicator Green light Normal operation Flashing green (short interval) Communicating Flashing amber (short interval) Sensing tag Flashing red (long interval) Communication error Flashing green (long interval) No tag Pin Signal 1 24V DC 2 Data + 3 GND 4 Data - 4 3 1 2 Table 12 - Cordsets No. of Pins Color Code Shield Wire Size [AWG] Cat. No. (1) (2) (1) Replace x with 5 [5 m (16.4 ft)] or 10 [10 m (33 ft)] for standard cable lengths. (2) Stainless steel connectors can be ordered by adding an S to the catalog number (example: Cat. No. 889DS-F5FC-J5). Straight Female Right Angle Female Straight Male Right Angle Male 4-pin A Foil Shield 22 889D-F5FC-Jx 889D-R5FC-Jx 889D-M5FC-Jx 889D-E5FC-Jx Table 13 - Patchcords No. of Pins Color Code Shield Wire Size [AWG] Cat. No. (1) (2) Straight Female Straight Male Straight Female Right Angle Female Right Angle Female Straight Male Right Angle Female Right Angle Male 4-pin A Foil Shield 22 889D-F5FCDM-Jx 889D-F5FCDE-Jx 889D-R5FCDM-Jx 889D-R5FCDE-Jx (1) Replace x with 0M3 [0.3 m (11.8 in.)], 1 [1 m (3.3 ft], 5 [5 m (16.4 ft)], or 10 [10 m (33 ft)] for standard cable lengths. (2) Stainless steel connectors can be ordered by adding an S to the catalog number (example: Cat. No. 889DS-F5FCDM-J5). Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 17 RFID Specifications — Tags Tags Our line of RFID reusable read/write tags allow for flexibility in information and application. ISO 15693 is an open standard for high frequency 13.56 MHz RFID. ICODE tags are available in many different styles and sizes to fit most applications. • ICODE ISO 15693 compliant • Multiple physical and memory sizes available • Passive tags (no battery) • 64 to 2K Bytes tags Disc Tag — ICODE SLI, SLIx, and SL2 Memory Available as 8 mm, 10 mm, 12 mm, 16 mm, 20 mm, 20 mm mount on metal, 30 mm, 35 mm high-impact resistant, 50 mm, and 51 mm high-temperature tags. Specifications Table 14 - 8 mm, 10 mm, 12 mm, and 16 mm Tags Attribute 8 mm (Cat. No. 56RF-TG-8) 10 mm (Cat. No. 56RF-TG-10) 12 mm (Cat. No. 56RF-TG-12MOM) 16 mm (Cat. No. 56RF-TG-16) Features • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits Chip type SLI SLI SLIx SLI Typical operating frequency 13.56 MHz 13.56 MHz 13.56 MHz 13.56 MHz External diameter 7.5 ± 0.2 mm (0.3 ± 0.01 in.) 9.5 ± 0.3 mm (0.4 ± 0.01 in.) 12.4 ± 0.25 mm (0.5 ± 0.01 in.) 16.0 ± 0.2 mm (0.6 ± 0.01 in.) Thickness 1.0 ± 0.3 mm (0.04 ± 0.01 in.) 1.0 ± 0.3 mm (0.04 ± 0.01 in.) 2.15 ± 0.50 mm (0.08 ± 0.02 in.) 3.0 ± 0.2 mm (0.1 ± 0.01 in.) Weight 110 ± 20 mg (0.004 ± 0.0007 oz) 110 ± 20 mg (0.004 ± 0.0007 oz) 0.6 ± 0.12 g (0.021 ± 0.004 oz) 1.0 ± 0.15 g mm (0.035 ± 0.005 oz) Material Epoxy Epoxy PPS (housing) and epoxy (potting) FORTRON 6165A6 (PPS) Color Yellowish Yellowish Black White (natural) Package quantity 25 units (plastic bag) 25 units (plastic bag) 25 units (plastic bag) 25 units (plastic bag) Mechanical • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) — Chemical/environmental Water IP67 (1 m/24 hr) Water IP67 (1 m/24 hr) • Water IP68 (1 m/24 hr) • 100 hrs, 20 °C (68 °F): Salt mist, fuel B, petroleum, and mineral/vegetable oils • 100 hrs, 20 °C (68 °F): HCl (10%), bleach (5%), caustic soda (PH 11), Perchloroethylene (100%), and neutralizing agent • 100 hrs, 70 °C (158 °F): Industrial laundry detergent (PH 10…11) and hydrogen peroxide (5%) Compliance Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Temperature, storage -40…+85 °C (-40…+185 °F) 1000 hr -40…+85 °C (-40…+185 °F) 1000 hr -40…+90 °C (-40…+194 °F) 1000 h -25…+85 °C (-13…+185 °F) 1000 hr Temperature, peak 100 °C (212 °F) 1 hr 100 °C (212 °F) 1 hr 120 °C (248 °F) 100 hr 120 °C (248 °F) 100 hr Temperature, operating -25…+85 °C (-13…+185 °F) -25…+85 °C (-13…+185 °F) -40…+85 °C (-40…+185 °F) -25…+85 °C (-13…+185 °F) Temperature, shock/ fatigue -40…+85 °C (-40…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) -40…+85 °C (-40…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) -40…+90 °C (-40…+194 °F) 100 cycles (soaking time 5 min, transition time 30 s) 20…160 °C (68…320 °F) 100 cycles (soaking time 5 min, transition time 30 s) 18 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Tags Table 15 - 20 mm, 30 mm, 35 mm High-impact Resistant, and 50 mm Tags Attribute 20 mm (Cat. No. 56RF-TG-20) 30 mm (Cat. No. 56F-TG-30) 35 mm High Impact Resistant (Cat. No. 56RF-TG-35HIR) 50 mm (Cat. No. 56RF-TG-50) Features • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits Chip type SLI SLI SLI SLI Typical operating frequency 13.56 MHz 13.56 MHz 13.56 MHz 13.56 MHz External diameter 20.0 ± 0.5 mm (0.8 ± 0.02 in.) 30.0 ± 0.5 mm (1.2 ± 0.02 in.) 34.0 ± 0.3 mm (1.3 ± 0.01 in.) 50.0 ± 0.5 mm (2.0 ± 0.02 in.) Central hole diameter — 5.2 ± 0.3 mm (0.2 ± 0.01 in.) 5.6 ± 0.3 mm (0.2 ± 0.01 in.) 5.2 ± 0.3 mm (0.2 ± 0.01 in.) Thickness 3.0 ± 0.5 mm (0.1 ± 0.02 in.) 3.0 ± 0.5 mm (0.1 ± 0.02 in.) 8.0 ± 0.3 mm (0.3 ± 0.01 in.) 3.5 ± 0.5 mm (0.1 ± 0.02 in.) Weight 1.3 ± 0.3 g (0.05 ± 0.01 oz) 3.0 ± 0.6 g (0.1 ± 0.02 oz) 7.8 ± 0.6 g (0.3 ± 0.02 oz) 9.5 ± 2.0 g (0.3 ± 0.07 oz) Material PA6 PA6 PA6 High Impact PA6 Color Black 9205 Black 9205 Black 9205 Black 9205 Package quantity 25 units (plastic bag) 25 units (plastic bag) 25 units (plastic bag) 25 units (plastic bag) Mechanical • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) Chemical/environmental Water IP69K (2 m/24 hr) Water IP69K (2m/24 hr) Water IP69K (2m/24 hr) Water IP69K (2m/24 hr) Compliance Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Temperature, storage -40…+90 °C (-40…+194 °F) 1000 h -40…+90 °C (-40…+194 °F) 1000 h -40…+90 °C (-40…+194 °F) 1000 h -40…+90 °C (-40…+194 °F) 1000 h Temperature, peak 140 °C (284 °F) 100 h 140 °C (284 °F) 100 hr 100 °C (212 °F) 100 hr 140 °C (284 °F) 100 hr Temperature, operating -20…+85 °C (-4…+185 °F) -20…+85 °C (-4…+185 °F) -25…+85 °C (-13…+185 °F) -20…+85 °C (-4…+185 °F) Temperature, shock/ fatigue -20…+85 °C (-4…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) -20…+85 °C (-4…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) -30…+90 °C (-22…+194 °F) 50 cycles (soaking time 10 min, transition time 30 s) -20…+85 °C (-4…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) Table 16 - 20 mm Mount on Metal and 51 mm High-temperature Tags Attribute 50 mm Mount on Metal (Cat. No. 56RF-TG-50MOM) 51 mm High-temperature (Cat. No. 56RF-TG-50HT) Features • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits • 1024 bits memory size (32 blocks of 4 bytes) • 896 user bits Chip type SLI SL2 Typical operating frequency 13.56 MHz 13.56 MHz External diameter 55 ± 0.25 mm (2.2 ± 0.01 in.) 51.0 x 51.0 ± 0.5 mm (2.0 x 2.0 ± 0.02 in.) Thickness 5.5 ± 0.1 mm (0.2 ± 0.004 in.) 6.5 ± 0.5 mm (0.3 ± 0.02 in.) Central Hole diameter 13 mm (0.5 in.) 5.5 ± 0.5 mm (0.2 ± 0.02 in.) Counterbore 10.5 mm (0.413 in.) Weight 30 ± 6 g (1.1 ± 0.2 oz) 30 g (1.06 oz) typical Material Acc. to ISO 1874: PA6T/6I-GF50 Acc. to ASTM: PPA, Polyphthalamide CAS number 25750-23-6 PPS plastics Color Black Black Package quantity 10 units (plastic bag) 25 units (plastic bag) Mechanical • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) Chemical/environmental Water IP69K (2m/24 hr) IP68 Compliance Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 Temperature, storage -40…+90 °C (-40…+194 °F) 1000 h -55…+185 °C (-67…+365 °F) (cumulative time more than 1500 h) Temperature, peak 140 °C (284 °F) 100 hr • 200 °C (392 °F)/60 min • 220 °C (428 °F)/45 min • 240 °C (464 °F)/30 min Temperature, operating -25…+85 °C (-13…+185 °F) -25…+85 °C (-13…+185 °F) IMPORTANT For information about the testing of our high-temperature tags, see High-temperature Tag Testing on page 28. Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 19 RFID Specifications — Tags Memory Organization The memory contains 1024 bit, organized in 32 blocks of 4 bytes each. The values (in hexadecimal notation) shown in the previous are stored in the EEPROM after the wafer production process. The contents of blocks that are marked with an x in Table 17 are not defined at delivery. With read and write commands only blocks 0…27 can be addressed. Table 17 - Memory Organization Byte 0 Byte 1 Byte 2 Byte 3 Block -4 UID0 UID1 UID2 UID3 Unique Identifier (lower bytes) Block -3 UID4 UID5 UID6 UID7 Unique Identifier (higher bytes) Block -2 Internally used EAS AFI DSFID EAS, AFI, DSFID Block -1 00 00 00 00 Write Access Conditions Block 0 x x x x User Data Block 1 x x x x Block 2 x x x x Block 3 x x x x Block 4 x x x x Block 5 x x x x Block 6 x x x x Block 7 x x x x Block 8 x x x x Block 9 x x x x Block 10 x x x x Block 11 x x x x Block 12 x x x x Block 13 x x x x Block 14 x x x x Block 15 x x x x Block 16 x x x x Block 17 x x x x Block 18 x x x x Block 19 x x x x Block 20 x x x x Block 21 x x x x Block 22 x x x x Block 23 x x x x Block 24 x x x x Block 25 x x x x Block 26 x x x x Block 27 x x x x User Data 20 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Tags Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 12 - Tag Dimensions 1.0±0.3 (0.040±0.012) Ø7.5±0.3 (0.295±0.012) 1.0±0.3 (0.040±0.012) Ø9.50±0.3 (0.347±0.012) Ø16.0±0.2 (0.630±0.008) 2.9±0.1 (0.114±0.004) Ø20.0±0.5 (0.787±0.020) 3.0±0.5 (0.100±0.020) Ø30.0±0.5 (1.180±0.020) Ø5.2±0.3 (0.205±0.012) 3.0±0.5 (0.100±0.020) Ø34.0±0.3 (1.339±0.012) Ø5.6±0.3 (0.220±0.012) 8.0±0.3 (0.315±0.012) Ø50.0±0.5 (1.969±0.020) Ø5.2±0.43 (0.205±0.017) 3.5±0.5 (0.118±0.020) Ø55.0±0.5 (2.166±0.02) 13.0±0.5 (0.512±0.02) Ø5.2±0.43 (0.205±0.017) 51±0.5 (2.008±0.02) Ø10.5 (0.413) Ø5.5 (0.217) 6.5 (0.256) 51±0.5 (2.008±0.02) 56RF-TG-8 56RF-TG-10 56RF-TG-16 56RF-TG-20 56RF-TG-30 56RF-TG-35HIR 56RF-TG-50 56RF-TG-50MOM 56RF-TG-50HT Ø12.40±0.25 (0.49±0.01) 2.15 (0.085) 2.00 (0.079) 56RF-TG-12MOM Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 21 RFID Specifications — Tags Disc Tag — ICODE FRAM Memory Available as 20 mm, 30 mm, 50 mm, and 50 mm mount on metal tags. Specifications Table 18 - 20 mm, 30 mm, 50 mm, and 50 mm Mount on Metal Attribute 20 mm (Cat. No. 56RF-TG-20-2KB) 30 mm (Cat. No. 56RF-TG-30-2KB) 50 mm (Cat. No. 56RF-TG-50-2KB) 50 mm Mount on Metal (Cat. No. 56RF-TG-50-2KBMOM) Features • 16 kbits FRAM® memory that is organized in 256 blocks of 8 bytes • High endurance memory: 1010 writings • Data retention >10 years [at ≤55° C (131 ° F)] • 16 kbits FRAM memory that is organized in 256 blocks of 8 bytes • High endurance memory: 1010 writings • Data retention >10 years [at ≤55° C (131 ° F)] • 16 kbits FRAM memory that is organized in 256 blocks of 8 bytes • High endurance memory: 1010 writings • Data retention >10 years [at ≤55° C (131 ° F)] • 2 kbytes FRAM memory (including 2000 bytes of user area) that is organized in 256 blocks of 8 bytes • High endurance memory: 1010 writings • Data retention 10 years [at 70° C (158 ° F)] Typical operating frequency 13.56 MHz 13.56 MHz 13.56 MHz 13.56 MHz External diameter 20.0 ± 0.5 mm (0.8 ± 0.02 in.) 30.0 ± 0.5 mm (1.2 ± 0.02 in.) 50.0 ± 0.5 mm (2.0 ± 0.02 in.) 55.0 ± 0.5 mm (2.2 ± 0.02 in.) Central hole diameter — 5.2 ± 0.3 mm (0.2 ± 0.01 in.) 5.2 ± 0.3 mm (0.2 ± 0.01 in.) 5.2 ± 0.3 mm (0.2 ± 0.01 in.) Thickness 3.0 ± 0.5 mm (0.1 ± 0.02 in.) 3.0 ± 0.5 mm (0.1 ± 0.02 in.) 3.5 ± 0.5 mm (0.1 ± 0.02 in.) 13.0 ± 0.5 mm (0.5 ± 0.02 in.) Weight 1.3 ± 0.3 g (0.05 ± 0.01 oz) 3.0 ± 0.6 g (0.1 ± 0.02 oz) 9.5 ± 2.0 g (0.3 ± 0.07 oz) 9.5 ± 2.0 g (0.3 ± 0.07 oz) Material PA6 PA6 PA6 PA6 modified - SOK001 Color Black 9205 Black 9205 Black 9205 Black Package quantity 25 units (plastic bag) 25 units (plastic bag) 25 units (plastic bag) 10 units (plastic bag) Mechanical • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) Chemical/environmental Water IP69K (2m/24 hr) Water IP69K (2m/24 hr) Water IP69K (2m/24 hr) Water IP69K (2m/24 hr) Compliance Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Temperature, storage -40…+90 °C (-40…+194 °F) 1000 h -40…+90 °C (-40…+194 °F) 1000 h -40…+90 °C (-40…+194 °F) 1000 h -40…+90 °C (-40…+194 °F) 1000 h Temperature, peak 140 °C (284 °F) 100 hr 140 °C (284 °F) 100 hr 140 °C (284 °F) 100 hr 140 °C (284 °F) 100 hr Temperature, operating -20…+85 °C (-4…+185 °F) -20…+85 °C (-4…+185 °F) -20…+85 °C (-4…+185 °F) -20…+85 °C (-4…+185 °F) Temperature, shock/ fatigue -20…+85 °C (-4…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) -20…+85 °C (-4…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) -20…+85 °C (-4…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) -20…+85 °C (-4…+185 °F) 50 cycles (soaking time 5 min, transition time 30 s) 22 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Tags Memory Organization The memory has 2000 bytes for use as user area and 48 bytes for use as system area. The total area consists of 256 blocks (250 blocks of user area and 6 blocks of system area). Each block can store 64 bits (8 bytes) of data. The block is the unit that is used for data writing and reading. Table 19 - Memory Organization Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 13 - Tag Dimensions Area Block No. User 00 H 01 H 02 H … … F8 H F9 H System FAH UID FBH EAS, AFI, DSFID, lock status FC H Write Access Status FD H Write Access Status FEH Write Access Status FF H Write Access Status Ø20.0±0.5 (0.790±0.02) 3.0±0.5 (0.110±0.02) Ø30.0±0.5 (1.180±0.02) Ø5.2±0.3 (0.205±0.012) 3.0±0.5 (0.110±0.02) Ø50.0±0.5 (1.970±0.02) Ø5.2±0.43 (0.205±0.017) 3.0±0.5 (0.110±0.02) Ø55.0±0.5 (2.166±0.02) 13.0±0.5 (0.512±0.02) Ø5.2±0.43 (0.205±0.017) 56RF-TG-20-2KB 56RF-TG-30-2KB 56RF-TG-50-2KB 56RF-TG-502KBMOM Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 23 RFID Specifications — Tags Disc Tag — ICODE Large FRAM Memory Available as a 30 mm 8 Kb tag. Specifications Table 20 - General Specifications Memory Organization The FRAM has 8192 bytes for use as a user area and 1024 bytes designated as the system area. The user areas consist of 256 blocks. Each block can store 256 bits (32 bytes) of data. The block is the unit that is used for the writing and reading of FRAM data. Table 21 - Memory Organization Attribute 30 mm 8 Kb (Cat. No. 56RF-TG-30-8KB) Features • Memory capacity of 9 kBytes FRAM (including 8192 bytes of user area) • 32-byte/block configuration, 256 blocks • Endurance: 1012 writes and reads to memory • Data Retention: 10 years (85 °C [185 °F)]) Typical operating frequency 13.56 MHz External diameter 30 ± 0.5 mm (1.2 ± 0.02 in.) Central hole diameter 5.2 ± 0.3 mm (0.2 ± 0.01 in.) Thickness 3.0 ± 0.5 mm (0.1 ± 0.02 in.) Weight 3.0 g (0.1 oz) Material According to ISO 1874: PA6T/6I-GF50 According to ASTM: PPA, Polyphthalamide CAS number 25750-23-6 Color Black Package quantity 10 units (plastic bag) Mechanical • Shock (IEC 68-2-29) • Vibration (IEC 68-2-6) Chemical/environmental Water IP69K (2m/24 hr) Compliance Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Temperature, storage -40…+90 °C (-40…+194 °F) 1000 h Temperature, peak 140 °C (284 °F) 100 hr Temperature, operating -20…+85 °C (-4…+185 °F) Temperature, shock/ fatigue -40…+90 °C (-40…+194 °F) 50 cycles (soaking time 5 min, transition time 30 s) Area Block Number (RF) Logical Address (SPI) Details Access RF Communication SPI Communication User area (8192 bytes) 000H…0FFH (1 block = 256 bit) 0000 H…0FFF H (1 address = 16 bit) User area Read/write Read/write System area (1024 bytes) 100 H 1000 H…100F H BSS (Block Security Status) Read Read 101 H 1010 H…101F H RLS (Read Lock Status) Read Read 102 H 1020 H…102F H SRL (SPI Read Lock) Read Read 103 H 1030 H…103F H SWL (SPI Write Lock) Read Read 11EH 11E0 H…11EE H AFI, DSFID Read Read UID Read Read 24 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Tags Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 14 - Tag Dimensions Paper Tag — ICODE SLIx and SLI Memory Available as 50 x 50 mm and 54 x 86 mm tags. Specifications Figure 15 - Structure Attribute 50 x 50 mm (Cat. No. 56RF-TG-5050) 54 x 86 mm (Cat. No. 56RF-TG-5486) Chip type ICODE SLIx NXP ICODE SLI Typical operating frequency 13.56 MHz Bend diameter >50 mm, tension less than 10 N Face Opaque Matt Paper 79 Backing Siliconized Paper 56 Antenna Aluminum, crimped coil Aluminum Adhesive RA-2RA-2 Operating temperature, electronic parts -40…+85 °C (-40…+185 °F) -25…+85 °C (-13…+185 °F) Labeling temperature, min 5 °C (41 °F) Usage temperature -10…+120 °C (14…248 °F) Peel, min 8 N / 25 mm (FTM 2) Printability Flexography and TTR with selected ribbons. Do not print over IC area. Compliance Compliant with ISO/IEC 15693 and 18000-3 Mode 1 Ø30.0±0.5 (1.180±0.02) Ø5.2±0.3 (0.205±0.012) 3.0±0.5 (0.110±0.02) 56RF-TG-20-2KB IC Face Material Antenna Coil PET Substrate Adhesive Backing Paper with Silicone Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 25 RFID Specifications — Tags Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 16 - Paper Tag Dimensions — Catalog Number 56RF-TG-5050 Description Dimension A1 x A2 Coil size 47 x 47 ± 0.5 mm (1.9 x 1.9 ± 0.02 in.) B1 x B2 Die-cut size 50 x 50 ± 0.2 mm (2.0 x 2.0 ± 0.01 in.) C Web width 54 ± 0.5 mm (2.1 ± 0.02 in.) D Pitch, length per piece MD 56 ± 1.5 mm (2.2 ± 0.06 in.) E Die-cut to web edge 2 ± 1.5 mm (0.08 ± 0.06 in.) F Die-cut to register mark 1.5 ± 1.0 mm (0.06 ± 0.04 in.) G Coil to die-cut (MD) 1.5 ± 1.5 mm (0.06 ± 0.06 in.) H Coil to die-cut (CD) 1.5 ± 1.5 mm (0.06 ± 0.06 in.) Thickness of the IC 120 μm ± 15% Overall thickness of transponder package (excluding IC and siliconized paper) 208 μm ± 10% Thickness of the siliconized paper 56 μm ± 5% D B1 C B2 E H A1 A2 F G MARKING OF BAD ONES UNWINDING DIRECTION 26 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Tags Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 17 - Paper Tag Dimensions—Catalog Number 56RF-TG-5486 Description Dimension A1 x A2 Coil size 50 x 82 ± 0.5 mm (2.0 x 3.2 ± 0.02 in.) B1 x B2 Die-cut size 54 x 86 ± 0.2 mm (2.1 x 3.4 ± 0.01 in.) C Web width 57 ± 0.5 mm (2.2 ± 0.02 in.) D Pitch, length per piece MD 96 ± 1.5 mm (3.8 ± 0.06 in.) E Die-cut to web edge 1.5 ± 1.5 mm (0.06 ± 0.06 in.) F Die-cut to register mark 3.5 ± 1.0 mm (0.1 ± 0.04 in.) G Coil to die-cut (MD) 2 ± 1.5 mm (0.08 ± 0.06 in.) H Coil to die-cut (CD) 2 ± 1.5 mm (0.08 ± 0.06 in.) Thickness of the IC 150 μm ± 10% Overall thickness of transponder package (excluding IC and siliconized paper) 205 μm ± 10% Thickness of the siliconized paper 56 μm ± 5% D A1 C A2 B2 B1 E F G H MARKING OF BAD ONES UNWINDING DIRECTION Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 27 RFID Specifications — Tags Proximity ISO Card — ICODE SLI Memory Available as a 85.60 x 53.98 mm tag. Specifications Approximate Dimensions Dimensions are shown in mm (in.). Dimensions that are shown are not intended to be used for installation purposes. Figure 18 - Proximity ISO Card Dimensions Attribute Cat. No. 56RF-TG-5486SC Card type ICODE SLI Typical operating frequency 13.56 MHz Length 85.6 ± 0.12 mm (3.4 ± 0.005 in.) Width 53.98 ± 0.05 mm (2.1 ± 0.002 in.) Thickness 0.76 ± 0.08 mm (0.03 ± 0.003 in.) Material PVC, white/white (glossy) Color White/white Temperature, operating -35…+50 °C (-31…+122 °F) Printing Both sides are fully printable with various technologies 85.60 (3.37) 53.98 (2.13) 28 Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 RFID Specifications — Tags High-temperature Tag Testing The following tests are conducted on our high-temperature tags. Temperature Test Profile — Catalog Number 56RF-TG-50HT Catalog number 56RF-TG-50HT high temperature tags are tested according to the following profile: 1. Tested at 60 °C (140 °F) 2. Placed in an oven at 185 °C (365 °F) for 30 minutes and then 240 °C (464 °F) for 30 minutes 3. Removed from oven and tested at 60 °C (140 °F) The cycle was repeated after 20 minutes. Time at Elevated Temperature The length of time the tags can withstand elevated temperature depends on the temperature. Figure 19 - Elevated Temperature Graph Table 22 - Time at Elevated Temperature Temperature Time 200 °C (392 °F) 60 min 220 °C (428 °F) 45 min 240 °C (464 °F) 30 min x 60° (140°) 185° (365°) Time (minutes) 3 3 4 20 30 y Temperature [°C (°F)] Non-operating Operating (Read/write) Rockwell Automation Publication 56RF-TD001E-EN-P - July 2019 29 RFID Specifications Additional Resources These documents contain additional information concerning related products from Rockwell Automation. You can view or download publications at http://www.rockwellautomation.com/global/literature-library/overview.page . Resource Description Bulletin 56RF RFID Industrial Radio Frequency Identification Brochure, publication RFID-BR001 Provides an overview of the entire RFID product line. Bulletin 56RF RFID Industrial Radio Frequency Identification User Manual, publication 56RF-UM001 Provides information to design, install, program, or troubleshoot control systems that use Bulletin 56RF RFID products. Bulletin 56RF RFID High Frequency 13.56 MHz RFID EtherNet/IP Interface Block Installation Instructions, publication 56RF-IN008 Provides information to install and configure RFID EtherNet/IP™ interface blocks. Bulletin 56RF RFID Square 40 mm x 40 mm Transceiver Installation Instructions, publication 56RF-IN009 Provides information to install and configure square (40 x 40 mm) transceivers. Bulletin 56RF RFID 18 mm Cylindrical Transceiver Installation Instructions, publication 56RF-IN012 Provides information to install and configure 18 mm cylindrical transceivers. Bulletin 56RF RFID 30 mm Cylindrical Transceiver Installation Instructions, publication 56RF-IN013 Provides information to install and configure 30 mm cylindrical transceivers. Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines to install a Rockwell Automation® industrial system. Product Certifications website, rok.auto/certifications Provides declarations of conformity, certificates, and other certification details. Allen-Bradley, LISTEN. THINK. SOLVE., Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 56RF-TD001E-EN-P - July 2019 Supersedes Publication 56RF-TD001D-EN-P - December 2018 Copyright © 2019 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A. Rockwell Automation Support Use the following resources to access support information. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf. Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. www.rockwellautomation.com/knowledgebase Local Technical Support Phone Numbers Locate the phone number for your country. www.rockwellautomation.com/global/support/get-support- now.page Direct Dial Codes Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. www.rockwellautomation.com/global/support/direct- dial.page Literature Library Installation Instructions, Manuals, Brochures, and Technical Data. www.rockwellautomation.com/literature Product Compatibility and Download Center (PCDC) Get help determining how products interact, check features and capabilities, and find associated firmware. www.rockwellautomation.com/global/support/pcdc.page Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.